nu-TRAC®
Triaxial Antenna Cable


Performance Summary Table
(go back and download PDF files for nu-TRAC details)
e-mail || Homepage
Performance Properties TRC-
500
TRC-
875
TRC-
1250
Conductor: (note 1) 0.190" 0.349" 0.527"
Dielectric: Cellular PE (note 2) 0.500" 0.920" 1.350"
Inner Shield: Aluminum Tape (note 3) 0.506" 0.926" 1.356"
Outer Shield: Aluminum Tape (note 3) 0.590" 1.013" 1.440"
Jacket: Black PE (note 4) 0.720" 1.200" 1.670"
Bend Radius (note 5) 3.5" 6.5" 13.5"
Weight (lbs/foot) 0.196 0.491 0.742
Temperature Range -40°C to +80°C
Impedance 50 Ohms
Velocity (%) 86 %
VSWR (typical) 150-900 MHz 1.2:1
Attenuation (dB/100'); 150 MHz 1.10 0.55 0.39
Attenuation (dB/100'); 450 MHz 2.00 0.97 0.79
Attenuation (dB/100'); 900 MHz 3.10 1.60 1.23
Coupling Loss @ 150 MHz 75 dB
Coupling Loss @ 450 MHz 80 dB
Coupling Loss @ 900 MHz 80 dB
The data presented is for cable mounted to a reinforced concrete surface, secured with stainless steel clamps, to approximate a realistic installation.

Notes:
(1) Center Conductor in TRC-875 & TRC-1250 is Copper Tube
Center Conductor in TRC-500 is Copper Clad Aluminum
(2) Low loss, closed cell polyethylene foam
(3) Aluminum Laminated Tape bonded to Dielectric with Braided Drain Wire
(4) Black, UV Protected Polyethylene (FR Optional)
(5) Less than 1 ohm impedance change at bend